HVAC estimating software

Bid more HVAC work. Take off duct by size.

Equipment by tag from the schedules. Ductwork by size along each run. Diffusers and grilles by type. Refrigerant and condensate pipe by length.

Build your duct items once and Kredna works out the sheet and hangers from what you draw, priced with your own costs.

22'-0"
Rectangular duct, 24x12386 LF
Duct sheet, 24x122,316 SF
Supply diffusers96 EA

Illustration on a made-up plan.

What an HVAC takeoff carries.

Equipment and air devices are counted. Duct and pipe are drawn as runs, and the sheet and hangers come from the length and size through the item's parts.

What you take offHowCarried in
Equipment by tag
Rooftop units, split systems, exhaust fans and terminal units, from the equipment schedule.
CountEA
Rectangular duct
Width and height as item properties. The duct sheet is a part: length times perimeter, with your waste for seams.
LinearLF
Round duct
Diameter as an item property.
LinearLF
Hangers
A part on the duct item: one at each spacing along each run, at the spacing you set.
LinearEA
Flexible ductLinearLF
Fire, smoke and volume dampersCountEA
Supply diffusers, return and exhaust grilles
From the reflected ceiling plans and the diffuser schedule.
CountEA
Refrigerant and condensate pipingLinearLF
ThermostatsCountEA

Take off duct by size. Get the sheet.

Make a rectangular duct item with width and height as properties, and a part that works out the sheet around it: length times perimeter, with your waste for seams. Add a hanger part at your spacing. Draw each run, and change the size on a takeoff where it differs.

Round duct carries its diameter and its hangers. Flexible duct is drawn by the run.

The item editor over the drawing: an item's properties and its parts, each quantity a formula

Count equipment by tag from the schedules.

Count rooftop units, air handlers, fans and terminal units by tag from the mechanical plans and the equipment schedule. Settle who carries the curbs, supports and hoisting before you price them.

Count air devices from the ceiling plans.

Count supply diffusers, return grilles and exhaust grilles from the reflected ceiling plans and the diffuser schedule. Box one symbol and auto count counts its matches on that sheet. Check the count against the schedule before you price it.

Takeoff: a plan measured by item, with the job tree and its quantities beside it

Say what is in for controls and balancing.

Keep your clauses for testing and balancing and for controls in your company clause list, worded the way your company bids. Each job starts from that list, and the proposal carries your words.

Build your HVAC items once.

There is no HVAC starter pack. Make the items you price in your library once, each with its parts and quantity formulas, and every job copies them when it first uses them. For example:

  • Rooftop unit, split system, exhaust fan and terminal unit, each with setting and start-up labor
  • Rectangular duct with duct sheet and hangers, from its width and height
  • Round duct with hangers, and flexible duct
  • Fire or smoke damper and volume damper
  • Supply diffuser, return grille and exhaust grille
  • Refrigerant piping and condensate piping
  • Your clauses for the HVAC work and start-up, controls as the sequences describe, and power, roof framing and balancing by others

The prices are yours to set. A part without a price shows as Missing, never as zero, and every total that includes it is marked incomplete until you price it.

The library: folders of items and assemblies, each with its parts

Find the HVAC scope. Settle what is by others.

Set up the scope assistant for HVAC once: what to look for, the disciplines and spec sections to read, and what is usually by others. It reads the mechanical plans, schedules, details and control diagrams, highlights where your scope is with a jump to each spot, and flags work that is usually another trade's, such as:

  • Power wiring and disconnects
  • Structural supports and the framing of roof openings
  • Plumbing and gas piping to the equipment, unless listed
  • Fire alarm devices in the ducts, wired by the electrician
  • Cutting, patching and roofing at penetrations

AI findings need estimator review. Check quantities, costs and scope against the project documents before submitting a bid.

Moving from another takeoff tool?

Pick an item, measure on the sheet and watch the quantity total in the job tree. Build your items once in the library, and the takeoff, pricing and proposal all read the same job.

HVAC and sheet metal questions

Can Kredna take off ductwork by size?
Yes. Draw each run with an item whose size is a property: width and height for rectangular duct, diameter for round. A part on the rectangular duct item works out the sheet from the length and the perimeter.
Can I price duct by the pound?
Yes. Add a part to your duct item with your own formula for weight from the sheet area and the gauge, and price it per pound.
Which drawings does an HVAC takeoff use?
The mechanical plans and roof plans, the equipment, diffuser and fan schedules, the mechanical details, sections and piping diagrams, the control diagrams and sequences, and the reflected ceiling plans for diffuser locations.
What does the AI do on an HVAC job?
The scope assistant reads the documents you set it up for and points to where the HVAC work is, by sheet, so you can jump to each spot. It flags work that is usually another trade's and possible conflicts, such as equipment with no schedule entry, and can draft an RFI or an exclusion. It never counts or measures, and everything it drafts waits for you to accept it.
Does Kredna work in metric?
Yes. Set Kredna to metric and duct and pipe show in meters and sheet in square meters.

Bring a mechanical set you know.

See equipment, duct and the proposal come together on a job your company has bid.